3-way change-over ball valve T-hole, PN16 external thread G 2 1/4", DN 40, kvs 32 Body nickel-plated, hot-pressed brass Ball stainless steel Stem stainless steel Seal PTFE / EPDM O-ring Temperature of medium max. 100 °C Leakage rate A-AB air bubble-tight EN 12266 Leakage rate B-AB 1% of kvs
Linear actuator with rack 200 N, 7.0 s / 100 mm, AC/DC 24 V, modulating, MFT Stroke range 0...100 mm Manual override with push-button Control DC 0...10 V (0...32 V adjustable) Operating range DC 2...10 V, 0...32 V adjustable Position feedback DC 2...10 V, 0...10 V,adjustable Connection PVC cable 1m
Globe valve actuator (Retrofit), 500 N, AC 100...240 V, Open/close, 3-point, 200 s, Stroke 20 mm, IP54, Terminals
Globe valve actuator (Retrofit), 500 N, AC/DC 24 V, Open/close, 3-point, 200 s, Stroke 20 mm, IP54, Terminals
Spring-return actuator NC 20 Nm, < 75 s, 90° AC / DC 24...230 V, Open/Close IP 54, Manual override with integrated position stop Running time spring < 20 s Connection PVC cable 1m Emergency control closed with mounting kit for RKH mounted
Spring-return actuator NO 20 Nm, < 75 s, 90° AC / DC 24...230 V, Open/Close IP 54, Manual override with integrated position stop Running time spring < 20 s Connection PVC cable 1m Emergency control open with mounting kit for RKH mounted
Spring return actuator NC 10 Nm, 90 s adjustable, 90° AC/DC 24 V, modulating, MP-Bus IP 54, manual override with integrated position stop Running time spring <20 s Operating range DC 2...10 V, 0...32 V adjustable Position feedback DC 2...10 V, 0...10 V adjustable Connection cable PVC 1 m Emergency control function closed with mounting kit for RKH mounted
Damper actuator 40 Nm, 150 s adjustable, 95° AC/DC 24 V, modulating, MP-Bus IP54, manual override can be locked Operating range DC 2...10 V, 0...32 V adjustable Position feedback DC 2...10 V, 0...10 V, adjustable Connection cable PVC 1 m Selectable direction of rotation (right/left) Angle of rotation limitation mech. + elec.
Damper actuator 40 Nm, 150 s adjustable, 95° AC/DC 24 V, modulating, MP-Bus Operating range DC 2...10 V, 0...32 V adjustable Position feedback DC 2...10 V, 0...10 V adjustable IP54, manual override temporary/permanent Connection terminals IP54 Selectable direction of rotation (right/left)
Rotary actuator ball valve 20 Nm, 90° AC 230 V, Open/Close, 3-point Running time motor 90 s / 90° IP 66/67, Manual override with push-button Connection cable FRNC 1 m Direction of rotation reversible (right/left) Position indicator mechanical, plug-in
Contact us!
We look forward to your inquiry, do not hesitate.
| Gewerbering 3 D-87480 Weitnau | ||
| Call: | +49 (8375) 9292092 | |
| Email: | shop@hvac.de | |
Copyright © 2017-2025 Stuhr GmbH
Cookies help us to provide our website.
Here you can choose which cookies you want to allow and change your selection at any time.
You can find more information in our privacy policy.
In addition to technically necessary cookies, we only use cookies for statistical analysis.
Technically necessary cookies are always set.