Fan Optimiser AC / DC 24 V Optimising function for fans in VAV application Control with analogue- or MP-controller Output frequency range converter 0...10 V MP data bus interface for up to 8 VAV-controllers Connection for PC-Tool and adjusters Terminal connection Control cabinet mounting
No longer available. Click for additional information or replacement guide...
Room temperature controller with 1 sequence AC 24 V Auto mode, without manual operation Setpoint: 18...35º C Temperature sensor: NTC internal o. external: 10...45º C 4 inputs: EHO, (Stand-by / C/O) 0...10 V shift, ext. temperature sensor 1 output: VAV 0/2...10 V Control characteristics: modulating, P-controller, P-Band switchable Housing colour white RAL...
3-step switch, button/LED Volume control 1 output VAV, AC 24 V Mode selection and display: COMF/MIN/MAX Setpoint COMF regulation under cover Housing colour white RAL 9003 Colour of socket light grey NSC 2005/R80B
Room temperature controller CRK24-B1 Heated/chilled ceiling 6-way valve AC 24 V Setpoint: 18...35º C, rotary button: +/- 3 K Select mode, display: AUTO / ECO / MAX 1 output: 6-way control valve 5 inputs: EHO, Stand-by, dewpoint setpoint adapt., ext. temp. sensor
NMV-D3-RE2-SET Retrofit kit VAV-Compact NMV-D3-RE2, 10 Nm for air speed 6 and 12 m/s AC/DC 24 V, 0/2...10 V, MP-Bus, contacts Incl. diff. pressure sensor, tube 6 mm Mounting instruction incl. Cardboard box packaging with template Stored Retrofit-TypeList
VRD3-RE2-SET Retrofit-Set VAV-Universal VRD3, NM24A-V for air speeds < 12m/s AC/DC 24 V, control signal 0/2...10 V, 10 Nm Accessories: diff. press. sensor, tube Mounting direction enclosed Cardboard box packaging with template
No longer available. Click for additional information or replacement guide...
Differential pressure sensor for VAV retrofit For round boxes up to 400 mm Comprising: Differential pressure sensor Accessory set in plastic bag: Seal, self-drilling screws, flat washers, tees Installation instructions
Room temperature controller with manual operation 2 heating levels, 1 VAV-sequence, AC 24 V Selection mode, display: AUTO / ECO / MAXIMUM Setpoint: 18...35º C, rotary button: +/- K Temperature sensor: NTC 10...45º C internal / external 5 outputs: EHO, Stand-by / Boost 0...10 V shift, ext. temperature limiter 3 outputs: VAV 0/2...10 V Heating for 1...3...
Room temp.controller, mode selection without button Regulation of volumetric flow or temperature 2 VAV and 1 heating valve outputs, AC24V Mode selection display: COMF / MIN / MAX Setpoint: 15...36°C, under cover: +/- K Temperature sensor: NTC 10...45º C internal/external 3 inputs: kitchen, bathroom, EHO 3 outputs: ZUL-/ABL-VAV 0/2...10 V, heating valve...
Room temperature controller, 2 sequences AC 24 V Auto mode, without manual operation Setpoint: 18...35º C Temperature sensor: NTC internal o. external: 10...45º C 5 inputs: EHO, stand-by, ventilation 0 ... 10 V shift, ext. temperature sensor 2 outputs: VAV 0 / 2...10 V, heating 3-point Control characteristics: modulating, P-controller, P-Band switchable...
Room control unit with operation Regulation of volumetric flow or temperature 2 VAV and 1 heating valve outputs, AC24V Mode selection display: COMF / MIN / MAX Setpoint: 15...36º C, rotary button: +/- K Temperature sensor: NTC 10...45º C internal/external 3 inputs: kitchen, bathroom, EHO 3 outputs: ZUL-/ABL-VAV 0/2...10 V, heating valve 3-pt or thermo...
Room temperature controller with 3 sequences AC 24 V Auto mode, without manual operation Setpoint: 18...35º C Temperature sensor: NTC internal o. external: 10...45º C 5 inputs: EHO, Stand-by, (C/O / Boost / dewpoint) 0...10 V shift, ext. temperature sensor 3 outputs: VAV 0 / 2...10 V, heating 3-point Heating / cooling 0...10 V Control characteristics:...
Contact us!
We look forward to your inquiry, do not hesitate.
Gewerbering 3 D-87480 Weitnau | ||
Call: | +49 (8375) 9292092 | |
Email: | shop@hvac.de |
Copyright © 2017-2024 Stuhr GmbH
Cookies help us to provide our website.
Here you can choose which cookies you want to allow and change your selection at any time.
You can find more information in our privacy policy.
In addition to technically necessary cookies, we only use cookies for statistical analysis.
Technically necessary cookies are always set.