MKC563.80-100K Control device PN25, safety function to DIN EN 14597, 2800 NControl devices with safety shut-off function per DIN EN 14597 for protection against excessive temperature and pressure in district heating, heating, ventilation and air conditioning systems. For open and closed circuits. With positioning control, position feedback signal and...
VPF44.50F15 Pressure independent control valves (PICVs) PN16 with flanged connectionsFor use in heating, ventilation, air conditioning systems and district heating as a control valve in closed circuits.
VPF44.50F25 Pressure independent control valves (PICVs) PN16 with flanged connectionsFor use in heating, ventilation, air conditioning systems and district heating as a control valve in closed circuits.
VPF44.65F35 Pressure independent control valves (PICVs) PN16 with flanged connections, DN 65, 5.1...35.8 m3/hFor use in heating, ventilation, air conditioning systems and district heating as a control valve in closed circuits.
VPF44.80F35 Pressure independent control valves (PICVs) PN16 with flanged connectionsFor use in heating, ventilation, air conditioning systems and district heating as a control valve in closed circuits.
VPF44.80F45 Pressure independent control valves (PICVs) PN16 with flanged connectionsFor use in heating, ventilation, air conditioning systems and district heating as a control valve in closed circuits.
VPF53.200F210 Combi valves (PICV), DN 200, 95...210 m3/h, PN25 with flanged connectionsFor use in heating, ventilating, air conditioning systems and district heating as a control valve in closed circuits
VPF53.200F280 Combi valves (PICV), DN 200, 130...280 m3/h, PN25 with flanged connectionsFor use in heating, ventilating, air conditioning systems and district heating as a control valve in closed circuits
VVF63.15-0.32 2-port valves, PN 40, DN 15, kvs 0.32, with flanged connectionsWith flanged connections to ISO 7005 For cooling, chilled, low and high temperature water, brine, heat transfer oils, saturated and superheated steam in open and closed circuits
VQI46.15F1.3 PICV, internally threaded, PN 25, DN 15, 300....1300 l/hPresettable PICVs, PN 25, internally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or cooling. heating systems...
VQI46.15L0.5Q PICV, internally threaded, PN 25, DN 15, 30...520 l/h, pressure test pointsPresettable PICVs, PN 25, internally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or...
VQI46.20F1.5 PICV, internally threaded, PN 25, DN 20, 320....1500 l/hPresettable PICVs, PN 25, internally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or cooling. heating systems...
Contact us!
We look forward to your inquiry, do not hesitate.
Gewerbering 3 D-87480 Weitnau | ||
Call: | +49 (8375) 9292092 | |
Email: | shop@hvac.de |
Copyright © 2017-2024 Stuhr GmbH
Cookies help us to provide our website.
Here you can choose which cookies you want to allow and change your selection at any time.
You can find more information in our privacy policy.
In addition to technically necessary cookies, we only use cookies for statistical analysis.
Technically necessary cookies are always set.