VQI46.15L0.5 PICV, internally threaded, PN 25, DN 15, 30...520 l/hPresettable PICVs, PN 25, internally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or cooling. heating systems for...
VQI46.20F1.5Q PICV, internally threaded, PN 25, DN 20, 320....1500 l/h, pressure test pointsPresettable PICVs, PN 25, internally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or...
VQP46.15F1.3 PICV, externally threaded, PN 25, DN 15, 300....1300 l/hPresettable PICVs, PN 25, externally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or cooling. heating systems...
VQP46.15L0.5 PICV, externally threaded, PN 25, DN 15, 30...520 l/hPresettable PICVs, PN 25, externally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or cooling. heating systems for...
VQP46.20F1.5Q PICV, externally threaded, PN 25, DN 20, 320....1500 l/h, pressure test pointsPresettable PICVs, PN 25, externally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or...
VQP46.25F1.8 PICV, externally threaded, PN 25, DN 25, 620....1800 l/hPresettable PICVs, PN 25, externally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or cooling. heating systems...
VQP46.25F1.8Q PICV, externally threaded, PN 25, DN 25, 620....1800 l/h, pressure test pointsPresettable PICVs, PN 25, externally threaded forventilation and air conditioning systems for water side control and automatic hydraulic balancing of air after-treatment devices, such as fan convectors, induction units, and in heat exchangers for heating or...
VVF63.100-150K 2-port seat valve, PN40, DN 100, kvs 150, with flanged connections, pressure compensatedWith flanged connections to ISO 7005 For cooling, chilled, low and high temperature water, brine, heat transfer oils, saturated and superheated steam in open and closed circuits
VVF63.125-220K 2-port seat valve, PN40, DN 125, kvs 220, with flanged connections, pressure compensatedWith flanged connections to ISO 7005 For cooling, chilled, low and high temperature water, brine, heat transfer oils, saturated and superheated steam in open and closed circuits
VVF63.15-0.8 2-port valves, PN 40, DN 15, kvs 0.8, with flanged connectionsWith flanged connections to ISO 7005 For cooling, chilled, low and high temperature water, brine, heat transfer oils, saturated and superheated steam in open and closed circuits
VVF63.15-1.25 2-port valves, PN 40, DN 15, kvs 1.25, with flanged connectionsWith flanged connections to ISO 7005 For cooling, chilled, low and high temperature water, brine, heat transfer oils, saturated and superheated steam in open and closed circuits
VVF63.15-2 2-port valves, PN 40, DN 15, kvs 2, with flanged connectionsWith flanged connections to ISO 7005 For cooling, chilled, low and high temperature water, brine, heat transfer oils, saturated and superheated steam in open and closed circuits
Contact us!
We look forward to your inquiry, do not hesitate.
Gewerbering 3 D-87480 Weitnau | ||
Call: | +49 (8375) 9292092 | |
Email: | shop@hvac.de |
Copyright © 2017-2024 Stuhr GmbH
Cookies help us to provide our website.
Here you can choose which cookies you want to allow and change your selection at any time.
You can find more information in our privacy policy.
In addition to technically necessary cookies, we only use cookies for statistical analysis.
Technically necessary cookies are always set.