2-way PI flow limiter valve, PN 25 Internal thread Rp 3/4", DN 20, Vnom 1900 l/h Housing Brass body Medium temperature 2...60 °C Leakage rate A, tight
2-way PI flow limiter valve, PN 25 Internal thread Rp 3/4", DN 20, Vnom 1500 l/h Housing Brass body Medium temperature 2...60 °C Leakage rate A, tight
2-way PI flow limiter valve, PN 25 Internal thread Rp 3/4", DN 20, Vnom 2900 l/h Housing Brass body Medium temperature 2...60 °C Leakage rate A, tight
2-way PI flow limiter valve, PN 25 Internal thread Rp 3/4", DN 20, Vnom 2350 l/h Housing Brass body Medium temperature 2...60 °C Leakage rate A, tight
Electr. 2-way PI-CCV Belimo Energy Valve™, Glycol monitoring Internal thread Rp 3/4", DN 20, Vnom 0.65 l/s AC/DC 24 V, modulating, communicative, hybrid Communication BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus Adjustable flow rate Vmax 30...100% of Vnom IP54 (for use of protective cap or grommet for RJ45 socket), Manual override with...
No longer available. Click for additional information or replacement guide...
Rotary actuator 160 Nm AC 24...240 V / DC 24...125 V, Open-close, 3-point, 2 x SPDT Running time motor 35 s / 90° Auxiliary switch note 1 x 10° / 1 x 0...90° (ex works 85°) IP66/67, Manual override with hand crank, can be fixed in any position Connection TerminalsRequired accessory for PR actuator (must be ordered separately):For butterfly valves DN...
Rotary actuator 160 Nm AC 24...240 V / DC 24...125 V, Open-close, 3-point, 2 x SPDT Running time motor 35 s / 90° Auxiliary switch note 1 x 10° / 1 x 0...90° (ex works 85°) IP66/67, Manual override with hand crank, can be fixed in any position Connection TerminalsRequired accessory for PR actuator (must be ordered separately):For butterfly valves DN...
2-way PI flow limiter valve, PN 25 Internal thread Rp 1", DN 25, Vnom 3600 l/h Housing Brass body nickel-plated Medium temperature 2...60 °C Leakage rate A, tight
Electr. 2-way PI-CCV Belimo Energy Valve™ SuperCap, Glycol monitoring Internal thread Rp 2", DN 50, Vnom 4.8 l/s AC/DC 24 V, modulating, communicative, hybrid Communication BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus Running time emergency control position 35 s / 90° Adjustable flow rate Vmax 30...100% of Vnom IP54 (for use of protective cap...
No longer available. Click for additional information or replacement guide...
Electr. 2-way PI-CCV Belimo Energy Valve™, Glycol monitoring Internal thread Rp 2", DN 50, Vnom 4.8 l/s AC/DC 24 V, modulating, communicative, hybrid Communication BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus Adjustable flow rate Vmax 30...100% of Vnom IP54 (for use of protective cap or grommet for RJ45 socket), Manual override with...
No longer available. Click for additional information or replacement guide...
Electr. 2-way PI-CCV Belimo Energy Valve™ SuperCap, Glycol monitoring Internal thread Rp 1 1/2", DN 40, Vnom 2.5 l/s AC/DC 24 V, modulating, communicative, hybrid Communication BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus Running time emergency control position 35 s / 90° Adjustable flow rate Vmax 30...100% of Vnom IP54 (for use of protective...
No longer available. Click for additional information or replacement guide...
Electr. 2-way PI-CCV Belimo Energy Valve™, Glycol monitoring Internal thread Rp 1 1/2", DN 40, Vnom 2.5 l/s AC/DC 24 V, modulating, communicative, hybrid Communication BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus Adjustable flow rate Vmax 30...100% of Vnom IP54 (for use of protective cap or grommet for RJ45 socket), Manual override with...
No longer available. Click for additional information or replacement guide...
Contact us!
We look forward to your inquiry, do not hesitate.
Gewerbering 3 D-87480 Weitnau | ||
Call: | +49 (8375) 9292092 | |
Email: | shop@hvac.de |
Copyright © 2017-2024 Stuhr GmbH
Cookies help us to provide our website.
Here you can choose which cookies you want to allow and change your selection at any time.
You can find more information in our privacy policy.
In addition to technically necessary cookies, we only use cookies for statistical analysis.
Technically necessary cookies are always set.