Catalog
Loading...
2-way open-close ball valve, ps 1600 kPa Internal thread 1 1/2", DN 40, kvs 31 m³/h Housing brass body nickel-plated Closing element stainless steel Stem stainless steel Stem seal O-ring EPDM Valve seat PTFE, O-ring EPDM Medium temperature -10...120°C Leakage rate A, air bubble tight (EN 12266-1)
Spring-return actuator NO 20 Nm, 90 s, 90° AC/DC 24 V, modulating, 2 x SPDT IP 54, Manual override with integrated position stop Running time spring < 20 s Control DC 0...10 V Operating range DC 2...10 V Position feedback DC 2...10 V Connection PVC cable 1m Auxiliary switch 2 integral Emergency control openYES with mounted kit BFV
No longer available. Click for additional information or replacement guide...
Mounting kit, Landis + Staefa LANDIS + STAEFA (Series 1), B3F... DN 20...40 B3G... DN 20...40
2-way open-close ball valve, ps 1600 kPa Internal thread 2", DN 50, kvs 49 m³/h Housing brass body nickel-plated Closing element stainless steel Stem stainless steel Stem seal O-ring EPDM Valve seat PTFE, O-ring EPDM Medium temperature -10...120°C Leakage rate A, air bubble tight (EN 12266-1)
Spring-return actuator NO 20 Nm, 90 s, 90° AC/DC 24 V, modulating, 2 x SPDT IP 54, Manual override with integrated position stop Running time spring < 20 s Control DC 0...10 V Operating range DC 2...10 V Position feedback DC 2...10 V Connection PVC cable 1m Auxiliary switch 2 integral Emergency control open with mounting kit for RKH mounted
3-way change-over ball valve, ps 1600 kPa Internal thread 1/2", DN 15, kvs 5.5 m³/h Housing brass body nickel-plated Closing element chrome-plated brass Stem nickel-plated brass Stem seal O-ring EPDM Valve seat PTFE, O-ring EPDM Medium temperature -10...100°C Leakage rate A, air bubble tight (EN 12266-1)
Spring-return actuator NC 20 Nm, < 75 s, 90° AC / DC 24...230 V, Open/Close IP 54, Manual override with integrated position stop Running time spring < 20 s Connection PVC cable 1m Emergency control closed with mounting kit for RKH mounted
Spring-return actuator NC 20 Nm, < 75 s, 90° AC / DC 24...230 V, Open/Close IP 54, Manual override with integrated position stop Running time spring < 20 s Connection PVC cable 1m Emergency control closedYES with mounted kit BFV
Spring-return actuator NO 20 Nm, < 75 s, 90° AC / DC 24...230 V, Open/Close IP 54, Manual override with integrated position stop Running time spring < 20 s Connection PVC cable 1m Emergency control openYES with mounted kit BFV
Contact us!
We look forward to your inquiry, do not hesitate.
Gewerbering 3 D-87480 Weitnau | ||
Call: | +49 (8375) 9292092 | |
Email: | shop@hvac.de |
Copyright © 2017-2024 Stuhr GmbH
Cookies help us to provide our website.
Here you can choose which cookies you want to allow and change your selection at any time.
You can find more information in our privacy policy.
In addition to technically necessary cookies, we only use cookies for statistical analysis.
Technically necessary cookies are always set.