Electr. 2-way PI-CCV Belimo Energy Valve™ with fail-safe function, Glycol monitoring Flange, DN 150, V'nom 45 l/s AC/DC 24 V, modulating, communicative, hybrid, Cloud Communication BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus Running time fail-safe 35 s / 90° Adjustable flow rate V'max 30...100% of Vnom IP40, Manual override with push-button...
No longer available. Click for additional information or replacement guide...
2-way Stainless steel globe valve, PN 25 Internal thread Rp 3/4", DN 20, kvs 4.4 m³/h Housing Stainless steel AISI 304 Fluid temperature 0...130°C Characteristic curve equal percentage Leakage rate max. 0.02% of the kvs value
No longer available. Click for additional information or replacement guide...
2-way Stainless steel globe valve, PN 25 Internal thread Rp 1", DN 25, kvs 8 m³/h Housing Stainless steel AISI 304 Fluid temperature 0...130°C Characteristic curve equal percentage Leakage rate max. 0.02% of the kvs value
No longer available. Click for additional information or replacement guide...
3-way Stainless steel globe valve, PN 25 Internal thread Rp 1/2", DN 15, kvs 1.9 m³/h Housing Stainless steel AISI 304 Fluid temperature 0...130°C Characteristic curve Control path A – AB: equal percentage, Bypass B – AB: Linear Leakage rate Control path A – AB: max. 0.02% of the kvs value Leakage rate Bypass B – AB: max. 0.02% of the kvs value
No longer available. Click for additional information or replacement guide...
3-way Stainless steel globe valve, PN 25 Internal thread Rp 3/4", DN 20, kvs 4.4 m³/h Housing Stainless steel AISI 304 Fluid temperature 0...130°C Characteristic curve Control path A – AB: equal percentage, Bypass B – AB: Linear Leakage rate Control path A – AB: max. 0.02% of the kvs value Leakage rate Bypass B – AB: max. 0.02% of the kvs value
No longer available. Click for additional information or replacement guide...
3-way Stainless steel globe valve, PN 25 Internal thread Rp 1", DN 25, kvs 8 m³/h Housing Stainless steel AISI 304 Fluid temperature 0...130°C Characteristic curve Control path A – AB: equal percentage, Bypass B – AB: Linear Leakage rate Control path A – AB: max. 0.02% of the kvs value Leakage rate Bypass B – AB: max. 0.02% of the kvs value
No longer available. Click for additional information or replacement guide...
6-way Characterised control valve, PN 16 Internal thread Rp 1/2", DN 15, kvs1 0.25 m³/h, kvs2 0.4 m³/h Housing Brass body Fluid temperature 6...80°C Characteristic curve Linear air-bubble tight, leakage rate A
6-way Characterised control valve, PN 16 Internal thread Rp 1/2", DN 15, kvs1 0.4 m³/h, kvs2 0.25 m³/h Housing Brass body Fluid temperature 6...80°C Characteristic curve Linear air-bubble tight, leakage rate A
6-way Characterised control valve, PN 16 Internal thread Rp 1/2", DN 15, kvs1 0.4 m³/h, kvs2 0.4 m³/h Housing Brass body Fluid temperature 6...80°C Characteristic curve Linear air-bubble tight, leakage rate A
6-way Characterised control valve, PN 16 Internal thread Rp 1/2", DN 15, kvs1 0.4 m³/h, kvs2 0.63 m³/h Housing Brass body Fluid temperature 6...80°C Characteristic curve Linear air-bubble tight, leakage rate A
6-way Characterised control valve, PN 16 Internal thread Rp 1/2", DN 15, kvs1 0.63 m³/h, kvs2 0.4 m³/h Housing Brass body Fluid temperature 6...80°C Characteristic curve Linear air-bubble tight, leakage rate A
Rotary actuator fail-safe (Retrofit) 20 Nm, NC AC 24...240 V / DC 24...125 V, Open/close, 2 x SPDT Running time motor 75 s / 90° Running time fail-safe <20 s / 90° Auxiliary switch note 1 x 10% / 1 x 11...90% IP54, Manual override by means of hand crank and locking switch Connection Cable 1 m PVC
Contact us!
We look forward to your inquiry, do not hesitate.
Gewerbering 3 D-87480 Weitnau | ||
Call: | +49 (8375) 9292092 | |
Email: | shop@hvac.de |
Copyright © 2017-2024 Stuhr GmbH
Cookies help us to provide our website.
Here you can choose which cookies you want to allow and change your selection at any time.
You can find more information in our privacy policy.
In addition to technically necessary cookies, we only use cookies for statistical analysis.
Technically necessary cookies are always set.